	<lastBuildDate>Thu, 04 Feb 2016 10:39:41 +0000</lastBuildDate>
	<language>fa-IR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://vcenter.ir/wp-content/uploads/2016/07/cropped-vcenter.ir-logo-32x32.png</url>
	<title>استوریج های سری NetApp FAS2200 Archives - راهکارهای جامع دیتاسنتر</title>
	<link>https://vcenter.ir/tag/استوریج-های-سری-netapp-fas2200/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>استوریج های سری NetApp FAS2200</title>
		<link>https://vcenter.ir/%d8%a7%d8%b3%d8%aa%d9%88%d8%b1%db%8c%d8%ac-%d9%87%d8%a7%db%8c-%d8%b3%d8%b1%db%8c-netapp-fas2200/</link>
					<comments>https://vcenter.ir/%d8%a7%d8%b3%d8%aa%d9%88%d8%b1%db%8c%d8%ac-%d9%87%d8%a7%db%8c-%d8%b3%d8%b1%db%8c-netapp-fas2200/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Thu, 04 Feb 2016 10:34:54 +0000</pubDate>
				<category><![CDATA[دسته‌بندی نشده]]></category>
		<category><![CDATA[استوریج های سری NetApp FAS2200]]></category>
		<guid isPermaLink="false">http://vcenter.ir/?p=2588</guid>

					<description><![CDATA[<p>استوریج های سری NetApp FAS2200 NetApp FAS2200 offers powerful, affordable, flexible data storage for midsized businesses and distributed enterprises. Key Points More powerful unified data storage systems start below $8,000.&#8230; </p>
<p>نوشته <a href="https://vcenter.ir/%d8%a7%d8%b3%d8%aa%d9%88%d8%b1%db%8c%d8%ac-%d9%87%d8%a7%db%8c-%d8%b3%d8%b1%db%8c-netapp-fas2200/">استوریج های سری NetApp FAS2200</a> اولین بار در <a href="https://vcenter.ir">راهکارهای جامع دیتاسنتر</a>. پدیدار شد.</p>
]]></description>
										<content:encoded><![CDATA[<p>استوریج های سری NetApp FAS2200</p>
<div class="row">
<div id="top_lead_hold" class="col-md-6">
<p class="lead">NetApp FAS2200 offers powerful, affordable, flexible data storage for midsized businesses and distributed enterprises.</p>
<div class="panel panel-default">
<div class="panel-heading">Key Points</div>
<ul class="list-group">
<li class="list-group-item">More powerful unified data storage systems start below $8,000.</li>
<li class="list-group-item">Integration with Windows and VMware simplifies management.</li>
<li class="list-group-item">Virtual Storage Tiering accelerates application performance.</li>
<li class="list-group-item">Automatic data movement between SSD and HDD increases storage efficiency.</li>
<li class="list-group-item">The cluster-ready systems can scale to 432TB.</li>
</ul>
</div>
<div class="pdf_thumb_hold">
<p><a href="http://www.broadberry.co.uk/system_files/datasheets/netapp-fas2200.pdf" target="blank"><img decoding="async" src="http://www.broadberry.co.uk/system_files/datasheet_thumbnails/8.jpg" alt="" /><em>NetApp FAS2200 Series [689.93K]</em></a></p>
<div class="clearBoth"></div>
</div>
</div>
<div class="col-md-6 z_index_98"><img decoding="async" id="top_lead_img" src="http://www.broadberry.co.uk/system_files/images/system_type_trans/14.png" alt="" /></div>
</div>
<div class="rightFeature">
<p><img decoding="async" src="http://www.broadberry.co.uk/img/netapp-fas2200.jpg" alt="" width="269" height="86" /></p>
<h4>Key Points</h4>
<ul>
<li>More powerful unified data storage systems start below $8,000.</li>
<li>Integration with Windows and VMware simplifies management.</li>
<li>Virtual Storage Tiering accelerates application performance.</li>
<li>Automatic data movement between SSD and HDD increases storage efficiency.</li>
<li>The cluster-ready systems can scale to 432TB.</li>
</ul>
</div>
<h2>NetApp FAS2200 Series</h2>
<p>NetApp FAS2200 offers powerful, affordable, flexible data storage for midsized businesses and distributed enterprises.</p>
<p>Midsized businesses and enterprises with distributed environments need powerful, flexible data storage to handle data growth. The NetApp FAS2200 series, named a &#8216;Champion&#8217; and &#8216;Best in Overall Value&#8217; by Info-Tech Research Group, is affordable, and is a more powerful storage platform than other systems in its class.</p>
<p><strong>Start right</strong> with unified storage for SAN and NAS. Accelerate application performance and optimize storage costs with NetApp Flash Accel Server Cache and Flash Pool Intelligent Caching.</p>
<p><strong>Keep it simple</strong> with intuitive storage management tools that integrate with key business applications and virtualisation environments. <strong><br />
</strong></p>
<p><strong>Grow smart</strong> while protecting your storage investment, with cluster-ready upgrades using the same NetApp operating system and software tools.</p>
<p>NetApp software on FAS2200 systems reduces disk purchases by 50% or more and cuts provisioning time by up to 90%.</p>
<p>The NetApp FAS2200 series delivers no-compromise unified storage, with industry-leading efficiency features at no additional cost, to boost performance and handle storage growth.</p>
<p>&nbsp;</p>
<div class="container">
<div class="page-header">
<h2>NetApp FAS2200 Series Specifications</h2>
</div>
<div id="accordion" class="jquery_accordian">
<h3>Technical Highlights</h3>
<div>
<table class="spec_tab_full" width="100%">
<tbody>
<tr>
<td class="leftHead" colspan="1" valign="top" width="135">SAN Protocol Support</td>
<td colspan="6" valign="top">IP SAN (iSCSI)</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Network Protocol Support</td>
<td colspan="6" valign="top">NFS V2/V3/V4 over UDP or TCP, PCNFSD V1/V2 for (PC) NFS client authentication, Microsoft CIFS, HTTP 1.0, HTTP 1.1 virtual hosts</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">LUNs</td>
<td colspan="6" valign="top">Up to 1,024</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">FlexVol Volumes</td>
<td colspan="6" valign="top">Up to 500 per controller</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Snapshot Copies</td>
<td colspan="6" valign="top">Up to 127,000 per controller</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Number of Supported Hosts</td>
<td colspan="6" valign="top">Up to 2 ports per controller configured as front-end (host) connectivity ports<br />
Up to 4 directly connected servers per active-active configuration<br />
Connected hosts per HA pair:</p>
<ul>
<li>Up to 256 SAN connected servers</li>
</ul>
</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Supported Configurations</td>
<td colspan="6" valign="top"><u>Controller Hardware Configurations</u><br />
Single controller, active-active or active-passive controllers in an HA pair<br />
<u>Back-End (Disk) Configurations</u><br />
Best practice: Dual-path with standalone and multipath HA storage (MP-HA) for HA pairs<br />
Supported: Single path with standalone or HA pairs</p>
<p>Operating in 7-Mode</p>
<ul>
<li>FAS2240 in Data ONTAP 8.1</li>
<li>FAS2220 in Data ONTAP 8.1.1</li>
</ul>
<p>Operating as clustered Data ONTAP</p>
<ul>
<li>FAS2240 in Data ONTAP 8.1</li>
<li>FAS2220 in Data ONTAP 8.1.1</li>
</ul>
</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Reliability</td>
<td colspan="6" valign="top">Redundant hot-swappable controllers, cooling fans, and power supplies</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Management</td>
<td colspan="6" valign="top">Full-duplex 10/100 Base-T Ethernet onboard console, diagnostic LED, Maintenance Center, SNMP, telnet, SSH, HTTP, Web (SSL), host scripting, e-mail alerts</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Security</td>
<td colspan="6" valign="top">Virus protection, SecureAdmin, CHAP authentication, role-based access control (RBAC)</td>
</tr>
</tbody>
</table>
</div>
<h3>Maximum RAID Group and Aggregate Sizes</h3>
<div>
<table class="spec_tab_full" width="100%">
<tbody>
<tr>
<td class="leftHead" valign="top" width="135">Maximum RAID Group Sizes</td>
<td colspan="7" valign="top">RAID 6 (RAID-DP)</p>
<ul>
<li>SAS and FC: 28 (26 data disks plus 2 parity disks)</li>
<li>SATA: 20 (18 data disks plus 2 parity disks)</li>
</ul>
<p>RAID 4</p>
<ul>
<li>SAS and FC: 14 (13 data disks plus 1 parity disk)</li>
<li>SATA: 7 (6 data disks plus 1 parity disk)</li>
</ul>
<p>RAID 6 + RAID 1 or RAID 4 + RAID 1 (SyncMirror)</td>
</tr>
<tr>
<td class="leftHead" valign="top">Volume/Aggregate</td>
<td valign="top">Maximum aggregate: 60TB raw, 54TB usable<br />
Maximum usable volume size: 53.7TB usable<br />
(no Snapshot copy reserve in either case)</td>
</tr>
</tbody>
</table>
</div>
<h3>Scalability</h3>
<div>
<table class="spec_tab_full" width="100%">
<tbody>
<tr class="head2">
<td valign="top" width="135"></td>
<td colspan="2" valign="top">FAS2240-2</td>
<td colspan="2" valign="top">FAS2240-4</td>
<td colspan="2" valign="top">FAS2220</td>
</tr>
<tr class="head1">
<td valign="top"></td>
<td valign="top">Active-Active<br />
Configuration</td>
<td valign="top">Single Controller</td>
<td valign="top">Active-Active<br />
Configuration</td>
<td valign="top">Single Controller</td>
<td valign="top">Active-Active<br />
Configuration</td>
<td valign="top">Single Controller</td>
</tr>
<tr>
<td class="leftHead" valign="top">Max. Raw Capacity</td>
<td valign="top">374TB</td>
<td valign="top">374TB</td>
<td valign="top">432TB</td>
<td valign="top">432TB</td>
<td valign="top">180TB</td>
<td valign="top">180TB</td>
</tr>
<tr>
<td class="leftHead" valign="top">Max. Number of Internal Disk Drives</td>
<td valign="top">24</td>
<td valign="top">24</td>
<td valign="top">24</td>
<td valign="top">24</td>
<td valign="top">12</td>
<td valign="top">12</td>
</tr>
<tr>
<td class="leftHead" valign="top">Max. Number of Expansion Disk Drives</td>
<td valign="top">120</td>
<td valign="top">120</td>
<td valign="top">120</td>
<td valign="top">120</td>
<td valign="top">48</td>
<td valign="top">48</td>
</tr>
<tr>
<td class="leftHead" valign="top">Max. Number of Total Disk Drives (Internal + External)</td>
<td valign="top">144</td>
<td valign="top">144</td>
<td valign="top">144</td>
<td valign="top">144</td>
<td valign="top">60</td>
<td valign="top">60</td>
</tr>
<tr>
<td class="leftHead" valign="top">Max. Drives per Back-End (Disk) FC Loop</td>
<td valign="top">84</td>
<td valign="top">84</td>
<td valign="top">84</td>
<td valign="top">84</td>
<td valign="top">N/A</td>
<td valign="top">N/A</td>
</tr>
<tr>
<td class="leftHead" valign="top">ECC Memory</td>
<td valign="top">12GB</td>
<td valign="top">6GB</td>
<td valign="top">12GB</td>
<td valign="top">6GB</td>
<td valign="top">12GB</td>
<td valign="top">6GB</td>
</tr>
</tbody>
</table>
</div>
<h3>Onboard I/O</h3>
<div>
<table class="spec_tab_full" width="100%">
<tbody>
<tr class="head2">
<td valign="top" width="135"></td>
<td colspan="2" valign="top">FAS2240-2</td>
<td colspan="2" valign="top">FAS2240-4</td>
<td colspan="2" valign="top">FAS2220</td>
</tr>
<tr class="head1">
<td valign="top"></td>
<td valign="top">Active-Active<br />
Configuration</td>
<td valign="top">Single Controller</td>
<td valign="top">Active-Active<br />
Configuration</td>
<td valign="top">Single Controller</td>
<td valign="top">Active-Active<br />
Configuration</td>
<td valign="top">Single Controller</td>
</tr>
<tr>
<td class="leftHead" valign="top">Onboard GbE Ports</td>
<td valign="top">8</td>
<td valign="top">4</td>
<td valign="top">8</td>
<td valign="top">4</td>
<td valign="top">8</td>
<td valign="top">4</td>
</tr>
<tr>
<td class="leftHead" valign="top">Onboard SAS Ports</td>
<td valign="top">4</td>
<td valign="top">2</td>
<td valign="top">4</td>
<td valign="top">2</td>
<td valign="top">4</td>
<td valign="top">2</td>
</tr>
<tr>
<td class="leftHead" valign="top">Modular I/O Slots</td>
<td valign="top">2</td>
<td valign="top">1</td>
<td valign="top">2</td>
<td valign="top">1</td>
<td valign="top">&#8211;</td>
<td valign="top">&#8211;</td>
</tr>
</tbody>
</table>
</div>
<h3>I/O Card Support</h3>
<div>
<table class="spec_tab_full" width="100%">
<tbody>
<tr class="head2">
<td valign="top" width="135"></td>
<td colspan="2" valign="top">FAS2240-2</td>
<td colspan="2" valign="top">FAS2240-4</td>
<td colspan="2" valign="top">FAS2220</td>
</tr>
<tr class="head1">
<td valign="top"></td>
<td valign="top">Active-Active<br />
Configuration</td>
<td valign="top">Single Controller</td>
<td valign="top">Active-Active<br />
Configuration</td>
<td valign="top">Single Controller</td>
<td valign="top">Active-Active<br />
Configuration</td>
<td valign="top">Single Controller</td>
</tr>
<tr>
<td class="leftHead" valign="top">Dual-Port 8/4/2Gb FC Disk Adapter (max.)</td>
<td valign="top">2</td>
<td valign="top">1</td>
<td valign="top">2</td>
<td valign="top">1</td>
<td valign="top">&#8211;</td>
<td valign="top">&#8211;</td>
</tr>
<tr>
<td class="leftHead" valign="top">Dual-Port 10GbE Ethernet Adapter</td>
<td valign="top">2</td>
<td valign="top">1</td>
<td valign="top">2</td>
<td valign="top">1</td>
<td valign="top">&#8211;</td>
<td valign="top">&#8211;</td>
</tr>
</tbody>
</table>
</div>
<h3>Software</h3>
<div>
<table class="spec_tab_full" width="100%">
<tbody>
<tr class="head2">
<td colspan="1" valign="top" width="135">Software</td>
<td valign="top">FAS2200 Series</td>
</tr>
<tr>
<td class="leftHead" valign="top">Operating System</td>
<td colspan="4" valign="top">Data ONTAP</td>
</tr>
<tr>
<td class="leftHead" valign="top">Operating Systems Supported</td>
<td colspan="4" valign="top">Windows 2000, Windows Server 2003, Windows XP, Linux, Sun Solaris, AIX, HP-UX, Mac OS, VMware ESX</td>
</tr>
<tr>
<td class="leftHead" valign="top">Standard Software</td>
<td colspan="3" valign="top"><u>Data ONTAP Essentials:</u></p>
<p>Efficiency: FlexVol, deduplication, compression and thin provisioning<br />
Availability: Multipath I/O, MultiStore<br />
Data Protection: RAID-DP, Snapshot, NearStore, and Open Systems SnapVault<br />
Performance: FlexShare<br />
Management: System Manager, Operations Manager, Protection Manager, Provisioning Manager</td>
</tr>
<tr>
<td class="leftHead" valign="top">Extended-Value Software (Licensed)</td>
<td colspan="3" valign="top">SnapManagerSuite: Application and virtual machine aware backup, recovery, and cloning (for Oracle, Exchange, SharePoint, SQL Server, SAP, Virtual Infrastructure, and Hyper-V)<br />
SnapRestore: Fast restore of Snapshot copies in seconds<br />
SnapMirror: Simple, efficient, and flexible disaster recovery<br />
FlexClone: Instant virtual copies of databases or virtual machines<br />
SnapVault: Disk-to-disk backup software for complete backups and online archives to primary or secondary storage in minutes instead of hours or days<br />
OnCommand Insight Balance for NetApp: Advanced analytics for physical and virtual environments<br />
Complete Bundle: All of the Extended-Value Software in a single bundle for all-inclusive convenience (Note: Insight Balance not included in Complete Bundle)</td>
</tr>
</tbody>
</table>
</div>
<h3>Storage Specifications</h3>
<div>
<table class="spec_tab_full" width="100%">
<tbody>
<tr>
<td class="leftHead" colspan="1" valign="top" width="135">Disk Shelves Supported (Fibre Channel, SATA, SAS)</td>
<td colspan="6" valign="top">DS14mk4 FC, DS14mk2 FC (only supported in Data ONTAP 8.1 with ESH4 shelf module), DS14mk2AT<br />
Each w/14 low-profile slots for FC and SATA disk drives*</p>
<p>DS2246<br />
With 24 slots for performance (SAS) HDD</p>
<p>DS4243 / DS4246<br />
With 24 slots for performance (SAS) HDD or capacity (SATA) HDD</p>
<p>* Not supported on FAS2220</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Disk Drive Support</td>
<td colspan="6" valign="top"><u>Disks Supported on New Configurations</u><br />
FAS2220</p>
<ul>
<li>Internal SSD: 100GB</li>
<li>Internal performance (SAS) HDD: 450GB, 600GB disks</li>
<li>Internal capacity (SATA) HDD: 1TB, 2TB, 3TB disks</li>
<li>External performance HDD: 300GB, 450GB, 600GB</li>
<li>External capacity HDD: 500GB, 1TB, 2TB, 3TB disks</li>
</ul>
<p>FAS2240-2</p>
<ul>
<li>Internal performance HDD: 450GB, 600GB disks</li>
<li>External FC: 300GB, 450GB, 600GB, 500GB, 1TB, 2TB</li>
<li>External performance HDD: 300GB, 450GB, 600GB</li>
<li>External capacity HDD: 500GB, 1TB, 2TB, 3TB disks</li>
</ul>
<p>FAS2240-4</p>
<ul>
<li>Internal SSD: 100GB</li>
<li>Internal capacity HDD: 1TB, 2TB, 3TB disks</li>
<li>External FC: 300GB, 450GB, 600GB</li>
<li>External performance HDD: 300GB, 450GB, 600GB</li>
<li>External capacity HDD: 500GB, 1TB, 2TB, 3TB disks</li>
</ul>
<p>&nbsp;</p>
<p><u>Disks Supported for Legacy (Controller Upgrade) Configurations (provided they are not beyond their end-of-support date) *</u><br />
FC: 36GB, 72GB, 144GB, 300GB disks<br />
SATA: 250GB, 320GB, 500GB, 750GB, 1TB disks</p>
<p>* Not supported on FAS2220</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Disk Shelf Support</td>
<td colspan="6" valign="top"><u>Shelves Supported</u><br />
Embedded Switched Hub4 (ESH4) *<br />
AT-FCX *<br />
IOM3<br />
IOM6</p>
<p>* Not supported on FAS2220</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Internal Disk Drive Storage Interface</td>
<td colspan="6" valign="top">Serial-Attached SCSI (SAS)</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Disk Drive Storage Shelf Interface</td>
<td colspan="6" valign="top">Serial-Attached SCSI (SAS) (FAS2220)</p>
<p>Serial-Attached SCSI (SAS) (FAS2240 with optional FC adapter for FC-AL storage connection)</td>
</tr>
<tr>
<td class="leftHead" colspan="1" valign="top">Power Supply/Cooling Fans</td>
<td colspan="6" valign="top">Dual, redundant, hot-pluggable, integrated power supply/fan assemblies (220V/110V)</td>
</tr>
</tbody>
</table>
</div>
<h3>System Specifications</h3>
<div>
<table class="spec_tab_full" width="100%">
<tbody>
<tr class="head2">
<td valign="top" width="135"></td>
<td valign="top">FAS2240-2</td>
<td valign="top">FAS2240-4</td>
<td valign="top">FAS2220</td>
</tr>
<tr>
<td class="leftHead" valign="top">AC Power/Current (line voltage for standalone systems dependent on local power distribution; system cabinets are 200 to 240VAC only)</td>
<td valign="top">88 to 264VAC, 0.9 to 4.8A, 50/60Hz</td>
<td valign="top">88 to 264VAC, 0.9 to 4.8A, 50/60Hz</td>
<td valign="top">88 to 264VAC, 9 to 4.5A, 50/60Hz</td>
</tr>
<tr>
<td class="leftHead" valign="top">Weight (fully loaded)</td>
<td valign="top">55.4 lbs (25.2 kg), HA with 24 disks</td>
<td valign="top">107.1 lbs (48.6 kg), HA with 24 disks</td>
<td valign="top">54.5 lb (24.7 kg) with 12 performance HDD</p>
<p>62.9 lb (28.5 kg) with 12 capacity HDD</td>
</tr>
<tr>
<td class="leftHead" valign="top">Height</td>
<td valign="top">3.35&#8243; (8.5 cm), fits into 2U space</td>
<td valign="top">7&#8243; (17.9 cm)</td>
<td valign="top">3.45&#8243; (8.76 cm), fits into 2U space</td>
</tr>
<tr>
<td class="leftHead" valign="top">Width</td>
<td colspan="3" valign="top">19&#8243; IEC rack-compliant (17.6&#8243;, 44.9 cm)</td>
</tr>
<tr>
<td class="leftHead" valign="top">Depth (without cable management brackets)</td>
<td valign="top">19&#8243; (48 cm)</td>
<td valign="top">24&#8243; (61 cm)</td>
<td valign="top">20&#8243; (50.8 cm)</td>
</tr>
<tr>
<td class="leftHead" valign="top">Operating Temperature, Altitude, and Relative Humidity</td>
<td colspan="3" valign="top">10F); at &lt;/= 3,000 m (at &lt;/= 10,000&#8242;) elevation; 20% to 80% relative humidity, noncondensing</td>
</tr>
<tr>
<td class="leftHead" valign="top">Nonoperating Temperature and Relative Humidity</td>
<td colspan="3" valign="top">-40C to 70C (-40F to 158F); at &lt;/= 12,192 m (at&lt;/= 40,000’) typical of unconditioned airplane cargo bay, 8% to 80% relative humidity, noncondensing, in original container</td>
</tr>
<tr>
<td class="leftHead" valign="top">Operating Acoustic Noise</td>
<td colspan="3" valign="top">FAS2220:</p>
<ul>
<li>Declared sound power (LwAd) per ISO 9296: 6.5 Bel</li>
<li>Sound pressure (LpAm) (bystander positions): 51.0 dB</li>
</ul>
<p>FAS2240-2:</p>
<ul>
<li>Declared sound power (LwAd) per ISO 9296: 6.9 Bel</li>
<li>Sound pressure (LpAm) (bystander positions): 51.0 dB</li>
</ul>
<p>FAS2240-4:</p>
<ul>
<li>Declared sound power (LwAd) per ISO 9296: 6.9 Bel</li>
<li>Sound pressure (LpAm) (bystander positions): 49.6 dB</li>
</ul>
</td>
</tr>
<tr>
<td class="leftHead" valign="top">Min. Cabinet Clearances for Airflow</td>
<td colspan="3" valign="top">25.4 cm (10 in) in front, 30.5 cm (12 in) in rear</td>
</tr>
<tr>
<td class="leftHead" valign="top">Min. Cabinet Clearances for Service</td>
<td colspan="3" valign="top">76.2 cm (30 in) in front, 76.2 cm (30 in) in rear</td>
</tr>
<tr>
<td class="leftHead" valign="top">Compliance</td>
<td colspan="3" valign="top">RoHS-compliant</td>
</tr>
<tr>
<td class="leftHead" valign="top">Safety / Emissions / Immunity</td>
<td colspan="3" valign="top">Safety: EN 60950, CE, CSA 60950, UL 60950, CB IEC60950-1 (all national deviations), EN60825-1, GOST-R, BSMI CNS14336, CCC GB 4943-2001, SABS, S Resolution 92-98</p>
<p>Emissions/Immunity: FCC Part 15 Class A, ICES-003, CE, MIC, VCCI, AS/NZS CISPR 22, EN55022, EN55024, IEC61000-3-2, IEC61000-3-3, CoC (South Africa), BSMI, KN22</p>
<p>EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, KN24, CISPR 24</td>
</tr>
</tbody>
</table>
</div>
<h3>FAS2200 System Power Specifications</h3>
<div>
<table class="spec_tab_full" width="100%">
<tbody>
<tr class="head2">
<td rowspan="2" valign="top" width="135">Model</td>
<td rowspan="2" valign="top">Input Voltage</td>
<td rowspan="2" valign="top"></td>
<td colspan="2" valign="top">Active-Active</td>
<td colspan="2" valign="top">Single Controller</td>
</tr>
<tr class="head_black">
<td valign="top">Typical</td>
<td valign="top">Maximum</td>
<td valign="top">Typical</td>
<td valign="top">Maximum</td>
</tr>
<tr>
<td class="leftHead" rowspan="4" valign="top">FAS2240-2</td>
<td rowspan="2" valign="top">100-120VAC</td>
<td valign="top">Power, W</td>
<td valign="top">356</td>
<td valign="top">474</td>
<td valign="top">269</td>
<td valign="top">390</td>
</tr>
<tr>
<td valign="top">Thermal, BTU/hr</td>
<td valign="top">1215</td>
<td valign="top">1618</td>
<td valign="top">919</td>
<td valign="top">1332</td>
</tr>
<tr>
<td rowspan="2" valign="top">200-240VAC</td>
<td valign="top">Power, W</td>
<td valign="top">339</td>
<td valign="top">456</td>
<td valign="top">262</td>
<td valign="top">379</td>
</tr>
<tr>
<td valign="top">Thermal, BTU/hr</td>
<td valign="top">1157</td>
<td valign="top">1557</td>
<td valign="top">895</td>
<td valign="top">1294</td>
</tr>
<tr>
<td class="leftHead" rowspan="4" valign="top">FAS2240-4</td>
<td rowspan="2" valign="top">100-120VAC</td>
<td valign="top">Power, W</td>
<td valign="top">545</td>
<td valign="top">582</td>
<td valign="top">482</td>
<td valign="top">533</td>
</tr>
<tr>
<td valign="top">Thermal, BTU/hr</td>
<td valign="top">1861</td>
<td valign="top">1987</td>
<td valign="top">1646</td>
<td valign="top">1820</td>
</tr>
<tr>
<td rowspan="2" valign="top">200-240VAC</td>
<td valign="top">Power, W</td>
<td valign="top">531</td>
<td valign="top">568</td>
<td valign="top">468</td>
<td valign="top">517</td>
</tr>
<tr>
<td valign="top">Thermal, BTU/hr</td>
<td valign="top">1813</td>
<td valign="top">1939</td>
<td valign="top">1598</td>
<td valign="top">1765</td>
</tr>
<tr>
<td class="leftHead" rowspan="4" valign="top">FAS2220</p>
<p>Capacity (SATA) HDD</td>
<td rowspan="2" valign="top">100-120VAC</td>
<td valign="top">Power, W</td>
<td valign="top">331</td>
<td valign="top">529</td>
<td valign="top">271</td>
<td valign="top">431</td>
</tr>
<tr>
<td valign="top">Thermal, BTU/hr</td>
<td valign="top">1130</td>
<td valign="top">1806</td>
<td valign="top">925</td>
<td valign="top">1471</td>
</tr>
<tr>
<td rowspan="2" valign="top">200-240VAC</td>
<td valign="top">Power, W</td>
<td valign="top">337</td>
<td valign="top">513</td>
<td valign="top">257</td>
<td valign="top">423</td>
</tr>
<tr>
<td valign="top">Thermal, BTU/hr</td>
<td valign="top">1287</td>
<td valign="top">1751</td>
<td valign="top">878</td>
<td valign="top">1444</td>
</tr>
<tr>
<td class="leftHead" rowspan="4" valign="top">FAS2220</p>
<p>Performance (SAS) HDD</td>
<td rowspan="2" valign="top">100-120VAC</td>
<td valign="top">Power, W</td>
<td valign="top">265</td>
<td valign="top">457</td>
<td valign="top">195</td>
<td valign="top">370</td>
</tr>
<tr>
<td valign="top">Thermal, BTU/hr</td>
<td valign="top">905</td>
<td valign="top">1560</td>
<td valign="top">665</td>
<td valign="top">1265</td>
</tr>
<tr>
<td rowspan="2" valign="top">200-240VAC</td>
<td valign="top">Power, W</td>
<td valign="top">258</td>
<td valign="top">440</td>
<td valign="top">192</td>
<td valign="top">360</td>
</tr>
<tr>
<td valign="top">Thermal, BTU/hr</td>
<td valign="top">881</td>
<td valign="top">1502</td>
<td valign="top">656</td>
<td valign="top">1229</td>
</tr>
</tbody>
</table>
</div>
</div>
<p><img decoding="async" id="corn8px_tl" src="http://www.broadberry.co.uk/img/layout/css/8px_corners/tl.png" alt="" /> <img decoding="async" id="corn8px_tr" src="http://www.broadberry.co.uk/img/layout/css/8px_corners/tr.png" alt="" /> <img decoding="async" id="corn8px_bl" src="http://www.broadberry.co.uk/img/layout/css/8px_corners/bl.png" alt="" /> <img decoding="async" id="corn8px_br" src="http://www.broadberry.co.uk/img/layout/css/8px_corners/br.png" alt="" /></div>
<div class="container">
<h3>NetApp FAS2200 Series Software</h3>
<p>FAS2200 systems come with the NetApp Data ONTAP operating system and advanced data management and data protection tools.</p>
<p>NetApp FAS2200 systems include a standard set of software products that deliver storage efficiency, simple data management, and high performance. Optional extended-value software products provide advanced capabilities, including instant data recovery, instant cloning, data replication, disk-to-disk backup, and application-aware backup and recovery.</p>
<table class="spec_tab_full" cellspacing="0">
<thead></thead>
<tbody>
<tr>
<td class="leftHead">Included Software</td>
<td><strong>Data ONTAP Essentials:</strong></p>
<p><strong>Efficiency:</strong> FlexVol, deduplication, compression and thin provisioning</p>
<p><strong>Availability:</strong> Multipath I/O, MultiStore</p>
<p><strong>Data protection:</strong> RAID-DP, Snapshot, NearStore, and Open Systems SnapVault</p>
<p><strong>Performance:</strong> FlexShare</p>
<p><strong>Management:</strong> System Manager, Operations Manager, Protection Manager, Provision Manager<br />
Data Protocols<br />
All supported Data Protocol licenses included</td>
</tr>
<tr>
<td class="leftHead">Extended-Value Software (optional)</td>
<td>
<ul>
<li><strong>Complete Bundle</strong>
<ul>
<li>SnapRestore</li>
<li>SnapMirror</li>
<li>SnapVault</li>
<li>FlexCone</li>
<li>SnapManager Suite</li>
</ul>
</li>
<li><strong>OnCommand Balance for NetApp</strong></li>
</ul>
</td>
</tr>
<tr>
<td class="leftHead">Software Description</td>
<td><strong>SnapRestore</strong>: Fast restore of Snapshot copies in seconds</p>
<p><strong>SnapMirror</strong>: Simple, efficient, and flexible disaster recovery</p>
<p><strong>SnapVault</strong>: Disk-to-disk backup software for complete backups and online archives to primary or secondary storage in minutes instead of hours or days</p>
<p><strong>FlexClone</strong>: Instant virtual copies of databases or virtual machines</p>
<p><strong>SnapManager</strong><strong>suite</strong>: Application and virtual machine-aware backup, recovery, and cloning (for Oracle, Exchange, SharePoint, SQL Server, SAP, virtual infrastructure, and Hyper-V)</p>
<p><strong>Complete Bundle:</strong> All of the Extended Value software, together in a single bundle for all-inclusive convenience</p>
<p><strong>OnCommand Balance for NetApp</strong>: Advanced analytics for physical and virtual environments (Note: not included in Complete Bundle)</td>
</tr>
</tbody>
</table>
<p><img decoding="async" id="corn8px_tl" src="http://www.broadberry.co.uk/img/layout/css/8px_corners/tl.png" alt="" /> <img decoding="async" id="corn8px_tr" src="http://www.broadberry.co.uk/img/layout/css/8px_corners/tr.png" alt="" /> <img decoding="async" id="corn8px_bl" src="http://www.broadberry.co.uk/img/layout/css/8px_corners/bl.png" alt="" /> <img decoding="async" id="corn8px_br" src="http://www.broadberry.co.uk/img/layout/css/8px_corners/br.png" alt="" /></div>
<div class="container">
<h2>Compare FAS2200 Models</h2>
<table class="spec_tab_full" border="0" width="100%" cellspacing="1" cellpadding="0">
<tbody>
<tr class="head2">
<td>Features</td>
<td width="124">FAS2240-2</td>
<td width="124">FAS2240-4</td>
<td width="124">FAS2220</td>
</tr>
<tr>
<td></td>
<td><img decoding="async" src="http://www.netapp.com/us/media/fas22402u-71x59.gif" alt="netapp FAS2240-2" width="71" height="59" /></td>
<td><img decoding="async" src="http://www.netapp.com/us/media/fas22404u-71x59.gif" alt="netapp FAS2240-4" width="71" height="59" /></td>
<td><img loading="lazy" decoding="async" src="http://www.netapp.com/us/media/fas2220-71x59.gif" alt="netapp FAS2220" width="71" height="59" /></td>
</tr>
<tr>
<td class="leftHead">Application environments</td>
<td colspan="3">Storage solutions for midsize businesses, remote or branch offices (ROBOs), and departments of large enterprises</td>
</tr>
<tr>
<td class="leftHead">Ideal for</td>
<td colspan="2">Higher performance or capacity needs</td>
<td>Value-oriented deployments</td>
</tr>
<tr>
<td class="leftHead">Storage networking support</td>
<td colspan="2">FC SAN, IP SAN, NAS</td>
<td>IP SAN, NAS</td>
</tr>
<tr>
<td class="leftHead" width="192">Full hardware redundancy</td>
<td width="130">Yes</td>
<td width="124">Yes</td>
<td width="124">Yes</td>
</tr>
<tr>
<td class="leftHead">Max. raw capacity</td>
<td>374TB</td>
<td>432TB</td>
<td>180TB</td>
</tr>
<tr>
<td class="leftHead">Max. disk drives</td>
<td>144</td>
<td>144</td>
<td>60</td>
</tr>
<tr>
<td class="leftHead">Disk drive types</td>
<td>SAS</td>
<td>SATA, SSD</td>
<td>SAS, SATA, SSD</td>
</tr>
<tr>
<td class="leftHead">Memory</td>
<td>12GB</td>
<td>12GB</td>
<td>12GB</td>
</tr>
<tr>
<td class="leftHead">Controller form factor</td>
<td>1 or 2 controllers in a single 2U chassis</td>
<td>1 or 2 controllers in a single 4U chassis</td>
<td>1 or 2 controllers in a single 2U chassis</td>
</tr>
<tr>
<td class="leftHead">Max. Gigabit Ethernet ports</td>
<td>8</td>
<td>8</td>
<td>8</td>
</tr>
<tr>
<td class="leftHead">Onboard SAS ports</td>
<td>4</td>
<td>4</td>
<td>4</td>
</tr>
<tr>
<td class="leftHead">NetApp Virtual Storage Tiering</td>
<td>Yes</td>
<td>Yes</td>
<td>Yes</td>
</tr>
<tr>
<td class="leftHead">8Gb Fibre Channel support</td>
<td>Yes*</td>
<td>Yes*</td>
<td>No</td>
</tr>
<tr>
<td class="leftHead">10Gb Ethernet support</td>
<td>Yes*</td>
<td>Yes*</td>
<td>No</td>
</tr>
<tr>
<td class="leftHead">Remote management</td>
<td>Yes</td>
<td>Yes</td>
<td>Yes</td>
</tr>
<tr>
<td class="leftHead">Storage protocols included</td>
<td>FC, iSCSI, CIFS, NFS</td>
<td>FC, iSCSI, CIFS, NFS</td>
<td>iSCSI, CIFS, NFS</td>
</tr>
</tbody>
</table>
<p class="greyOut">* Based on optional dual-port 10GbE or 8Gb FC mezzanine card and single slot per controller.</p>