<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>کانفیگ کردن SmartCache در سرورهای HP Archives - راهکارهای جامع دیتاسنتر</title>
	<atom:link href="https://vcenter.ir/tag/%da%a9%d8%a7%d9%86%d9%81%db%8c%da%af-%da%a9%d8%b1%d8%af%d9%86-smartcache-%d8%af%d8%b1-%d8%b3%d8%b1%d9%88%d8%b1%d9%87%d8%a7%db%8c-hp/feed/" rel="self" type="application/rss+xml" />
	<link>https://vcenter.ir/tag/کانفیگ-کردن-smartcache-در-سرورهای-hp/</link>
	<description>دیتاسنتر &#124; سرور &#124; استوریج &#124; مجازی سازی &#124; شبکه &#124; ذخیره سازی و بکاپ</description>
	<lastBuildDate>Tue, 02 Feb 2016 20:42:01 +0000</lastBuildDate>
	<language>fa-IR</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.0</generator>

<image>
	<url>https://vcenter.ir/wp-content/uploads/2016/07/cropped-vcenter.ir-logo-32x32.png</url>
	<title>کانفیگ کردن SmartCache در سرورهای HP Archives - راهکارهای جامع دیتاسنتر</title>
	<link>https://vcenter.ir/tag/کانفیگ-کردن-smartcache-در-سرورهای-hp/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>کانفیگ کردن SmartCache در سرورهای HP</title>
		<link>https://vcenter.ir/%da%a9%d8%a7%d9%86%d9%81%db%8c%da%af-%da%a9%d8%b1%d8%af%d9%86-smartcache-%d8%af%d8%b1-%d8%b3%d8%b1%d9%88%d8%b1%d9%87%d8%a7%db%8c-hp/</link>
					<comments>https://vcenter.ir/%da%a9%d8%a7%d9%86%d9%81%db%8c%da%af-%da%a9%d8%b1%d8%af%d9%86-smartcache-%d8%af%d8%b1-%d8%b3%d8%b1%d9%88%d8%b1%d9%87%d8%a7%db%8c-hp/#respond</comments>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Tue, 02 Feb 2016 20:42:01 +0000</pubDate>
				<category><![CDATA[دسته‌بندی نشده]]></category>
		<category><![CDATA[کانفیگ کردن SmartCache در سرورهای HP]]></category>
		<guid isPermaLink="false">http://vcenter.ir/?p=2542</guid>

					<description><![CDATA[<p>کانفیگ کردن SmartCache در سرورهای HP Here, I am using an embedded P420i controller installed in a HP Gen8 Server. I have also updated the controller firmware and ACU version&#8230; </p>
<p>نوشته <a href="https://vcenter.ir/%da%a9%d8%a7%d9%86%d9%81%db%8c%da%af-%da%a9%d8%b1%d8%af%d9%86-smartcache-%d8%af%d8%b1-%d8%b3%d8%b1%d9%88%d8%b1%d9%87%d8%a7%db%8c-hp/">کانفیگ کردن SmartCache در سرورهای HP</a> اولین بار در <a href="https://vcenter.ir">راهکارهای جامع دیتاسنتر</a>. پدیدار شد.</p>
]]></description>
										<content:encoded><![CDATA[<p>کانفیگ کردن SmartCache در سرورهای HP</p>
<p>Here, I am using an embedded P420i controller installed in a HP Gen8 Server. I have also updated the controller firmware and ACU version to the latest. I have used the Intelligent Provisioning feature of HP Gen8 Server and launched ACU from these. You can also ACU within the Operating System to configure HP SmartCache.</p>
<blockquote><p><strong>NOTE:</strong> If you are using HP Smart Storage Administrator, the interface will be slightly different. But the steps and procedure remains the same.</p></blockquote>
<p>1. Open Array Configuration utility on your Server. You can launch HP ACU or HP SSA (HP Smart Storage Administrator) from Intelligent Provisioning or from the Operating system (Windows, Linux etc).</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/HP-Smart-Cache-on-Gen8-Server.jpg" rel="prettyPhoto"><img fetchpriority="high" decoding="async" class="aligncenter no-display appear" title="HP Smart Cache on Gen8 Server" src="http://www.serverhead.com/wp-content/uploads/2014/06/HP-Smart-Cache-on-Gen8-Server_thumb.jpg" alt="HP Smart Cache on Gen8 Server" width="620" height="416" border="0" /></a></p>
<p>2. Select the HP Smart Array controller from the drop down menu as shown below.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Array-Configuration-Utility.jpg" rel="prettyPhoto"><img decoding="async" class="aligncenter no-display appear" title="Array Configuration Utility" src="http://www.serverhead.com/wp-content/uploads/2014/06/Array-Configuration-Utility_thumb.jpg" alt="Array Configuration Utility" width="620" height="408" border="0" /></a></p>
<p>3. As you can see from the below provided image, the HP Smart Array Controller P420 is connected to four 300GB SAS HDDs and two 200 GB Solid State Disk (SSD).</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Configure-HP-SmartCache-on-Proliant-Server.jpg" rel="prettyPhoto"><img decoding="async" class="aligncenter no-display appear" title="Configure HP SmartCache on Proliant Server" src="http://www.serverhead.com/wp-content/uploads/2014/06/Configure-HP-SmartCache-on-Proliant-Server_thumb.jpg" alt="Configure HP SmartCache on Proliant Server" width="620" height="407" border="0" /></a></p>
<p>4. Now let us create an Array using two SAS HDDs. To create array, click on <strong>Create Array</strong> button.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Configure-HP-SmartCache-on-Proliant-Server1.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Configure HP SmartCache on Proliant Server" src="http://www.serverhead.com/wp-content/uploads/2014/06/Configure-HP-SmartCache-on-Proliant-Server_thumb1.jpg" alt="Configure HP SmartCache on Proliant Server" width="620" height="407" border="0" /></a></p>
<p>5. Select <strong>SAS</strong>, select the HDDs and click <strong>OK</strong> button as shown below.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Create-a-SAS-ARRAY.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Create a SAS ARRAY" src="http://www.serverhead.com/wp-content/uploads/2014/06/Create-a-SAS-ARRAY_thumb.jpg" alt="Create a SAS ARRAY" width="620" height="451" border="0" /></a></p>
<p>6. Now the <strong>SAS Array A</strong> is created. Let us create a new Logical drive on this array.<br />
7. Click on <strong>Create logical drive</strong> button to create a new logical drive.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Create-Logical-Drive-in-Server.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Create Logical Drive in Server" src="http://www.serverhead.com/wp-content/uploads/2014/06/Create-Logical-Drive-in-Server_thumb.jpg" alt="Create Logical Drive in Server" width="620" height="446" border="0" /></a></p>
<p>8. Select the <strong>RAID</strong> and click on <strong>Save</strong> (Here, I have selected RAID 1).</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/RAID-1-on-HP-Proliant-Server.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="RAID 1 on HP Proliant Server" src="http://www.serverhead.com/wp-content/uploads/2014/06/RAID-1-on-HP-Proliant-Server_thumb.jpg" alt="RAID 1 on HP Proliant Server" width="620" height="447" border="0" /></a></p>
<p>9. Now you have successfully created the logical drive in SAS Array A.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Logical-drive-is-created-in-HP-ACU.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Logical drive is created in HP ACU" src="http://www.serverhead.com/wp-content/uploads/2014/06/Logical-drive-is-created-in-HP-ACU_thumb.jpg" alt="Logical drive is created in HP ACU" width="620" height="444" border="0" /></a></p>
<p>10. Now I will create one more Array and Logical drive using the remaining SAS HDDs.<br />
11. To Create another Array,  Select <strong>Unassigned drives</strong>, then click on <strong>Create Array</strong> button.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Create-a-RAID-Array-in-Proliant-Server.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Create a RAID Array in Proliant Server" src="http://www.serverhead.com/wp-content/uploads/2014/06/Create-a-RAID-Array-in-Proliant-Server_thumb.jpg" alt="Create a RAID Array in Proliant Server" width="620" height="445" border="0" /></a></p>
<p>12. Select <strong>SAS</strong>, select the HDDs and click on <strong>OK</strong> button as shown below.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Create-another-RAID-array-on-HP-Gen8-Server.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Create another RAID array on HP Gen8 Server" src="http://www.serverhead.com/wp-content/uploads/2014/06/Create-another-RAID-array-on-HP-Gen8-Server_thumb.jpg" alt="Create another RAID array on HP Gen8 Server" width="620" height="444" border="0" /></a></p>
<p>13. Now <strong>SAS Array B</strong> is created. Let us create a new Logical drive in this array.<br />
14. Click on <strong>Create Logical drive</strong> to create a new Logical drive.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Create-Multple-Logical-drive-on-SAS-Array-B.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Create Multple Logical drive on SAS Array B" src="http://www.serverhead.com/wp-content/uploads/2014/06/Create-Multple-Logical-drive-on-SAS-Array-B_thumb.jpg" alt="Create Multple Logical drive on SAS Array B" width="620" height="444" border="0" /></a></p>
<p>15. Select the <strong>RAID</strong> level and click on <strong>Save</strong> button as shown below.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/SAS-Array-B-Logical-Drive-creation.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="SAS Array B Logical Drive creation" src="http://www.serverhead.com/wp-content/uploads/2014/06/SAS-Array-B-Logical-Drive-creation_thumb.jpg" alt="SAS Array B Logical Drive creation" width="620" height="446" border="0" /></a></p>
<p>16. Now you have created a the <strong>logical drive 2</strong> under SAS array B</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/SAS-Array-B-with-RAID-1-Logical-drive-created.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="SAS Array B with RAID 1 Logical drive created" src="http://www.serverhead.com/wp-content/uploads/2014/06/SAS-Array-B-with-RAID-1-Logical-drive-created_thumb.jpg" alt="SAS Array B with RAID 1 Logical drive created" width="620" height="444" border="0" /></a></p>
<p>17. Now it is the time to <strong>enable HP SmartCache</strong> on the Controller.<br />
18. Click on the HP Smart Array Controller, then click on <strong>Enable HP SmartCache</strong> option as shown below.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Enable-HP-SmartCache-on-Server.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Enable HP SmartCache on Server" src="http://www.serverhead.com/wp-content/uploads/2014/06/Enable-HP-SmartCache-on-Server_thumb.jpg" alt="Enable HP SmartCache on Server" width="620" height="447" border="0" /></a></p>
<p>19. Select the option <strong>Solid State SAS</strong>, click <strong>Save</strong>.</p>
<blockquote><p><strong>NOTE:</strong> When you create SmartCache, you are not creating any more RAID logical drives on these SSDs. So you do not have to specify any RAID levels here. Moreover, you could not use any unused space on the SSD to create an array or logical drive. In short, once you make a SSD for SmartCache, it cannot be used for any other purpose at the same time.</p></blockquote>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Solid-State-SAS-for-Hp-SmartCache.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Solid State SAS for Hp SmartCache" src="http://www.serverhead.com/wp-content/uploads/2014/06/Solid-State-SAS-for-Hp-SmartCache_thumb.jpg" alt="Solid State SAS for Hp SmartCache" width="619" height="444" border="0" /></a></p>
<p>20. You will receive a warning. Click OK in the warning.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Enable-HP-SmartCache-on-Gen8-Server.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Enable HP SmartCache on Gen8 Server" src="http://www.serverhead.com/wp-content/uploads/2014/06/Enable-HP-SmartCache-on-Gen8-Server_thumb.jpg" alt="Enable HP SmartCache on Gen8 Server" width="620" height="464" border="0" /></a></p>
<p>21. It will create a new SmartCache Array on your Server as shown below.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/HP-SmartCache-is-created-on-HP-Server.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="HP SmartCache is created on HP Server" src="http://www.serverhead.com/wp-content/uploads/2014/06/HP-SmartCache-is-created-on-HP-Server_thumb.jpg" alt="HP SmartCache is created on HP Server" width="620" height="424" border="0" /></a></p>
<p>22. To assign a SmartCache to a logical drive, select the <strong>SmartCache Array C</strong> from left pane, click on<strong>Create HP SmartCache logical drive</strong> button as shown below.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Create-SmartCache-for-Logical-Drive.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Create SmartCache for Logical Drive" src="http://www.serverhead.com/wp-content/uploads/2014/06/Create-SmartCache-for-Logical-Drive_thumb.jpg" alt="Create SmartCache for Logical Drive" width="620" height="424" border="0" /></a></p>
<p>23. Now select the Logical drive for which you want to assign HP SmartCache.</p>
<blockquote><p><strong>NOTE:</strong> The recommended SmartCache is 10% of Logical drive as the first logical drive is 279 GB, it is recommended to set SmartCache size of first logical drive as 27.9 GB.</p></blockquote>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Select-HP-SmartCache-Logical-Drive.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Select HP SmartCache Logical Drive" src="http://www.serverhead.com/wp-content/uploads/2014/06/Select-HP-SmartCache-Logical-Drive_thumb.jpg" alt="Select HP SmartCache Logical Drive" width="620" height="444" border="0" /></a></p>
<p>24. Click on Save button once you are done. Now you have successfully created a 27.9 GB of Cache for your Logical drive 1 (RAID 1 with 279 GB).  Good Job</p>
<p>Now let us assign HP SmartCache for logical drive 2. You can repeat Step 23, 24, 25 and select Logical drive 2 to assign HP SmartCache for Logical drive 2. Here, you can try another method assign the HP SmartCache. Whatever the method you follow, the outcome is same.</p>
<p>25. To assign HP SmartCache for Logical Drive 2, here I will show you alternate method.<br />
26. Click on <strong>Logical Drive 2</strong> at the left pane of ACU window.<br />
27. Click on <strong>Create SmartCache for Logical drive</strong>  as shown below.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/HP-SmartCache-for-Logical-Drive-2.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="HP SmartCache for Logical Drive 2" src="http://www.serverhead.com/wp-content/uploads/2014/06/HP-SmartCache-for-Logical-Drive-2_thumb.jpg" alt="HP SmartCache for Logical Drive 2" width="619" height="446" border="0" /></a></p>
<p>28. Select the <strong>Recommended size</strong> option as shown below.</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/Logical-Drive-2-SmartCache-Assignment.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="Logical Drive 2 SmartCache Assignment" src="http://www.serverhead.com/wp-content/uploads/2014/06/Logical-Drive-2-SmartCache-Assignment_thumb.jpg" alt="Logical Drive 2 SmartCache Assignment" width="618" height="443" border="0" /></a></p>
<p>29. Now you have successfully configured HP SmartCache for both Logical Drive 1 and 2</p>
<p><a href="http://www.serverhead.com/wp-content/uploads/2014/06/HP-SmartCache-is-Configured-on-HP-Server.jpg" rel="prettyPhoto"><img loading="lazy" decoding="async" class="aligncenter no-display appear" title="HP SmartCache is Configured on HP Server" src="http://www.serverhead.com/wp-content/uploads/2014/06/HP-SmartCache-is-Configured-on-HP-Server_thumb.jpg" alt="HP SmartCache is Configured on HP Server" width="619" height="447" border="0" /></a></p>
<p>30. <strong>Congrats</strong>, you have successfully configured HP SmartCache on your Server.</p>
<p>You can notice that we have 316.6 GB of remaining HDD space on HP SmartCache Array C. This space can be used create more SmartCache for future logical drive that you might create. But you cant use this space for any RAID or storage.</p>
<p>نوشته <a href="https://vcenter.ir/%da%a9%d8%a7%d9%86%d9%81%db%8c%da%af-%da%a9%d8%b1%d8%af%d9%86-smartcache-%d8%af%d8%b1-%d8%b3%d8%b1%d9%88%d8%b1%d9%87%d8%a7%db%8c-hp/">کانفیگ کردن SmartCache در سرورهای HP</a> اولین بار در <a href="https://vcenter.ir">راهکارهای جامع دیتاسنتر</a>. پدیدار شد.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://vcenter.ir/%da%a9%d8%a7%d9%86%d9%81%db%8c%da%af-%da%a9%d8%b1%d8%af%d9%86-smartcache-%d8%af%d8%b1-%d8%b3%d8%b1%d9%88%d8%b1%d9%87%d8%a7%db%8c-hp/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>